One key to a successful DAA hip replacement is adequate visualization, which is aided by retractors. However, malpositioned retractors can cause femoral nerve palsy, a potentially serious neurological complication that can delay postoperative rehabilitation. In the January 15, 2020 issue of The Journal, Yoshino et al. report on a cadaveric study that quantifies the distance between the femoral nerve and the acetabular rim at varying points along the rim. Knowing these precise distances could help surgeons make safer decisions about where—and where not—to place retractors.
The authors dissected 84 cadaveric hips from 44 formalin-embalmed cadavers and measured the distance from the femoral nerve to various points along the acetabular rim by using a reference line drawn from the anterior superior iliac spine (ASIS) to the center of the acetabulum. They found the femoral nerve was closest to the rim (only 16.6 mm away) at the 90° point.
In addition, at 90°, the thickness of the iliopsoas muscle and the femoral length (a probable proxy for size of the patient) were positively associated with increased distance to the nerve. Other anatomic factors such as inguinal ligament length, femoral head diameter, and thickness of the capsule were not associated with the nerve-rim distance.
The degree nomenclature used by Yoshino et al. can be correlated to a clock-face representation of the acetabulum, with the 60° point at the 3 o’clock (anterior) position; the 30° point represents a relatively safe location for placement of the anterior inferior iliac spine retractor (see Figure above).
This important anatomic study can help us improve our mastery of musculoskeletal anatomy—and avoid, if possible, placement of retractors at 90° relative to a line drawn from the ASIS to the center of the acetabulum.
Matthew R. Schmitz, MD
JBJS Deputy Editor for Social Media